The Chiesa di San Michele Arcangelo in Castel Sant’Angelo, Cingoli, is undergoing damage repair and seismic upgrading. C&G Engineering is responsible for the structural design.
Location
Cingoli (MC) – Castel Sant’Angelo
Client
Diocese of Macerata
Period
From May 2021 – design ongoing
Works value
€ 1,000,000.00 (authorised amount)
Our role
Structural design and structural works supervision (Ing. N. Gobbi); co-design and structural site management (Ing. F. Cantarini)
The project
Damage repair and seismic upgrading of the Chiesa di San Michele Arcangelo in Castel Sant’Angelo, Cingoli (Decree ID 461 / Procedure ID 461). Post-2016 earthquake reconstruction under Ordinance 105/2020.
Structural design and modelling
The design is based on a 3D structural model of the masonry building and on the analysis of local collapse mechanisms. The images show the calculation model and the setting of the church in the village.